Automatic Blood Pressure Monitor 1WMPD4000206H

Page 2

41-2 Unpacking and Inspection CAUTION Handle this device carefully at all times. Strong shock to the device may cause trouble during operation.

Page 3 - WARNING DEFINITIONS

51-3 Specifications Table 1 Specifications Performance specifications General Power supply 120VAC 60 Hz (For USA area) 230VAC 50 Hz (For Europe a

Page 4 - COMPLIANCE

62. PART NAMES 2-1 Main Unit Fig.2 TM-2655/TM-2655P whole view Note  The printer unit is available only for the TM-265

Page 5 - SAFETY PRECAUTIONS

72-2 Rear Panel Fig.3 TM-2655/TM-2655P rear panel (The illustration above is not to scale.) 2-3 Symbols The symbols used with the TM-2655

Page 6 - GENERAL PRECAUTIONS

8What is An Irregular Heartbeat? The TM-2655P provides a blood pressure and pulse rate measurement even when an irregular heartbeat occurs. An irregu

Page 7 - CONTENTS

93.INSTALLATION Follow the procedure below to install the TM-2655/TM-2655P. 1. To ensure that the TM-2655/TM-2655P works properly, install the devic

Page 8

104. OPERATION 1. Turn on the POWER switch located on the rear panel. When the POWER switch is turned on, all of the display symbols will appear f

Page 9 - 1.INTRODUCTION

118. When the measurement is complete, the air is automatically released from the cuff and the cuff will become loose. 9. The measurement results

Page 10 - Fig.1 Items contained

125.SETTING THE CLOCK 5-1 Clock Adjustment Mode The clock is set in the clock adjustment mode. The clock adjustment mode display and switches used ar

Page 11 - 1-3 Specifications

138. Press the switch to display “14”. 9. Press the SELECT switch to make the minutes section of the TIME display flash. 10. Press the switch

Page 12 - 2. PART NAMES

© 2005 A&D Company Ltd. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated into any l

Page 13 - 2-3 Symbols

146. INSTALLING THE PRINTER PAPER (This chapter is applicable only to the TM-2655P.) With the power turned on, install the printer paper as follow

Page 14

157. SETTING THE FUNCTIONS 7-1 Function Setting Mode The TM-2655/TM-2655P is provided with various functions, which allow the user to set the devic

Page 15 - 3.INSTALLATION

167-2 Description of the Functions Table 5 Functions No. Function SYSTOLIC display DIASTOLIC display Description F01 f01 off Not available. off No

Page 16 - 4. OPERATION

177-3 Printing Samples High-speed printing Graph printing 4-line printing Table printing

Page 17

188. COMMUNICATION SPECIFICATIONS The TM-2655/TM-2655P is equipped with two RS-232C channels. Various settings for each channel are available in the

Page 18 - 5.SETTING THE CLOCK

198-2 Channel 2: D-sub 9-pin CAUTION  The personal computer and medical equipment connected to the device are not allowed to be in the patien

Page 19

209. MAINTENANCE 9-1 Replacing the Arm Cuff Cover Replace the arm cuff cover as follows: 1. Locate the cover at the bottom of the arm insertion sect

Page 20

219-2 Replacing the Fuses Replace the fuses as follows: 1. Remove the caps of both fuse holders located on the rear panel. 2. Replace both fuses

Page 21 - 7. SETTING THE FUNCTIONS

229-4 Error Codes Table 9 Error codes Error code Description pe The printer paper has run out. Install a new roll of printer paper. HU The printer

Page 22 - Table 5 Functions

239-7 Options and Consumables Options and consumables available for the TM-2655/TM-2655P are shown below. Order them from the nearest dealer. Use th

Page 23 - 7-3 Printing Samples

iWARNING DEFINITIONS The warnings described in this manual have the following meanings: WARNING Important information to alert you to a situati

Page 24 - Pin assignment

2410. TROUBLESHOOTING If the TM-2655/TM-2655P does not function properly or an error code appears, try the following corrective actions. Table 10

Page 25 - 8-2 Channel 2: D-sub 9-pin

2511.EXTERNAL DIMENSIONS Fig.20 External dimensions Note The illustration above indicates the TM-2655P with the printer unit

Page 29 - 9-7 Options and Consumables

iiCOMPLIANCE Compliance with the European Directive 93/42/EEC for Medical Products This device conforms to the following requirements: European Direc

Page 30 - 10. TROUBLESHOOTING

iiiSAFETY PRECAUTIONS WARNING Grounding To avoid electrical shock, connect the power cable to a medical electrical outlet having a ground termin

Page 31 - 11.EXTERNAL DIMENSIONS

ivGENERAL PRECAUTIONS Obey the following precautions for safe and correct usage. Precautions unique to the TM-2655/TM-2655P appear on the relevant

Page 32

1CONTENTS WARNING DEFINITIONS...ⅰ COMPLIANCE...

Page 33

29. MAINTENANCE.......20 9-1 Replacing the Ar

Page 34

31.INTRODUCTION 1-1 Features The TM-2655/TM-2655P is a blood pressure monitor that measures systolic and diastolic blood pressure and pulse. The TM-2