15 The Function Table
The function table is provided to store and reference items that determine the
performance of the scale. Each item has a parameter.
The parameters are maintained even without power applied.
15.1 The Procedure for Setting Parameters
Step 1 Turn off the display.
Press the ON/OFF switch while the ZERO switch is
pressed and held. The function table is displayed.
Step 2 Set parameters for each item using the following
switches.
^ switch Selecting the parameter of an item.
Selecting the value of a digit at f16.
< switch Selecting a digit at f16.
F switch Proceeding to the end of the table
without storing the parameter.
ENTER switch Storing a parameter for the current
item and proceeding to the next item.
Returning to normal mode from the
end of the table.
Step 3 Press the ENTER switch to return to the normal mode,
when end is displayed.
Note Pressing the ENTER switch on step 2, the parameter is
stored in the scale.
Note Pressing the F switch at any time will cause end to be
displayed. The press ENTER to return to the normal mode.