A&D UA-767PBT-C Instruction Manual

Browse online or download Instruction Manual for Blood pressure units A&D UA-767PBT-C. A&D UA-767PBT-C blood pressure unit User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 18
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Digital Blood Pressure Monitor
Model UA-767 BT-C
Instruction Manual
Original
Manuel d
instructions
Traduction
Manual de Instrucciones
Traducción
Manuale di Istruzioni
Traduzione
Bedienungsanleitung
Übersetzung
Gebruiksaanwijzing
Vertaling
使用手冊
1WMPD4002093C
翻譯
Page view 0
1 2 3 4 5 6 ... 17 18

Summary of Contents

Page 1 - Model UA-767 BT-C

Digital Blood Pressure Monitor Model UA-767 BT-C Instruction Manual Original Manuel d’instructions Traduction Manual de Instrucciones Trad

Page 2 - Contents

English 9 Using The Monitor Applying The Arm Cuff 1. Wrap the cuff around the upper arm, about 1-2 cm above the inside of the elbow, as shown.

Page 3 - Precautions

English 10 Measurements Model UA-767 BT-C is designed to detect the pulse and to inflate the cuff to a systolic pressure level automatically.

Page 4 - Contraindications

English 11 Measurements Measurement With The Desired Systolic Pressure If your systolic pressure is expected to exceed 230 mmHg or you use the opti

Page 5 - Parts Identification

English 12 What Is An Irregular Heartbeat Model UA-767 BT-C blood pressure monitor provides a blood pressure and pulse rate measurement even when

Page 6 - Symbols

English 13 Reference Material: Journal of Hypertension 1999, Vol 17 No.2 mmHg 11010510095908580Optimal 120 130 140 150 160 170 180 Systolic blood pre

Page 7 - Using The Monitor

English 14 Typical fluctuation within a day(Measured every five minutes)PM AM Time Blood pressure SystolicDiastolic Sleepdescribed in this manual to

Page 8

English 15 Maintenance Do not open the device. It uses delicate electrical components and an intricate air unit that could be damaged. If you canno

Page 9

English 16 Useful life Device: 5 years (when used six times a day) Cuff: 2 years (when used six times a day) Accessory AC adapter The adapter i

Page 10 - and Proper fit range

1-243 Asahi, Kitamoto-shi, Saitama 364-8585 JAPAN Telephone: [81] (48) 593-1111 Fax: [81] (48) 593-

Page 11 - Measurements

English 1 Contents Dear Customers ...2 Preliminary Remarks...

Page 12

English 2 Dear Customers Congratulations on purchasing a state-of-the-art A&D blood pressure monitor, one of the most advanced monitors availab

Page 13 - Pressure Bar Indicator

English 3 Used equipment, parts and batteries are not treated as ordinary household waste, and must be disposed of according to the applicable local

Page 14 - About Blood Pressure

English 4 Parts Identification Part of Display Pressure Bar Indicator MEMORYSystolic Pressure Diastolic PressurePulse Rate Battery Indicator I.H.B

Page 15 - Troubleshooting

English 5 Symbols Symbols Function / Meaning Recommended Action Standby and power on. Battery installation guide Direct current Type BF:

Page 16 - Technical Data

English 6 Symbols Function / Meaning Recommended Action Refer to instruction manual/booklet SN Serial number Polarity of DC jack Using

Page 17 - 139°C 2A

English 7 Using The Monitor Connecting The AC Adapter Insert the AC adapter plug into the DC jack. Next, connect the AC adapter to an electrical ou

Page 18 - A&D AUSTRALASIA PTY LTD

English 8 Using The Monitor Selecting The Correct Cuff Size Using the correct cuff size is important for an accurate reading. If the cuff is not t