A&D OP-04 Specifications

Browse online or download Specifications for Measuring, testing & control A&D OP-04. A&D OP-04 Product specifications User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Weighing Indicator

Weighing Indicator for Check Weighing Scales 1WMPD4002313

Page 2 - This Manual and Marks

8 5. NAMES AND FUNCTIONS No. NAMES FUNCTIONS / OPERATION WEIGHT DATA DISPLAY Indicates the weight data.

Page 3

9 No. NAMES FUNCTIONS / OPERATION COMPARISON INDICATORS Indicates the results of the weight comparison LO (RED), OK (GREEN) and HI (YELLOW).

Page 4 - 1. COMPLIANCE

10 6. FUNCTION PARAMETER SETTINGS To design a platform scale, set the capacity, weighing unit and other functions according to the specification

Page 5 - 2. INTRODUCTION

11 6-2. Function list Item Function number Description  C01- 0 CAL switch enabled, 0 key enabled C01- 1 CAL switch disabled, 0 key

Page 6 - 3. UNPACKING

12 7. CALIBRATION This function adjusts the scale (indicator) for accurate weighing. Calibration must be done when the FS-D is initially connect

Page 7 - 4-2. Load Cell Connections

13  If you need ZERO calibration but do not need SPAN calibration, turn the power off to exit from the calibration procedure. 7. To calibrate wi

Page 8 - Example of calculation:

14 8. AUTO-TARE FUNCTION The FS-D has an auto-tare function to be used with the comparator function enabled. If the weight value is within the OK

Page 9

15 9. ADDITIONAL INFORMATION This section describes the additional functions and corrections to the instruction manual of FS-i series (WM+PD40013

Page 10 - 5. NAMES AND FUNCTIONS

16 The frame ground and the shield are connected internally and there is no difference between them in use. Data format  Example of data Out of

Page 11

17 Command H I , + 0 0 1 0 0 CRLF Assume 2 decimal place number. Reply H I , + 0 0 1 0 0 CRLF 1.00% will be set as LO limit %. Command L O

Page 12

This Manual and Marks All safety messages are identified by the following, “WARNING” or “CAUTION”, of ANSI Z535.4 (American National Standard

Page 13 - 6-2. Function list

18 10. ERROR MESSAGES Overload error Warning to indicate that an object beyond the weighing capacity has been placed on the weighing pan. Remove

Page 14

19 11. SPECIFICATIONS 11-1. Capacity and minimum display C02- setting 0* 1 2 3 4 5 6 7 Capacity 6 15 30 60 150 300 600 1500 0.002* 0.005 0.01 0

Page 15 - -009.8050

20 11-3. Options OP-02 (HC-02i) SLA Battery (Yuasa Battery NP4-6 recommended.) OP-03 (FS-03i) RS-232C + Comparator Relay Output (See note.) OP-04

Page 17 - 9. ADDITIONAL INFORMATION

3-23-14 Higashi-Ikebukuro, Toshima-ku, Tokyo 170-0013 JAPAN Telephone: [81] (3) 5391-6132 Fax: [81] (3) 5391-6148 A&D ENGINEERING, IN

Page 18 - Data output mode (f06)

1 Contents 1. COMPLIANCE ... 2 2. INTRODUCTION ...

Page 19 - 9-3. OP-04 RS-422 / 485

2 1. COMPLIANCE Compliance with FCC rules  Please note that this equipment generates, uses and can radiate radio frequency energy. This equipme

Page 20

3 2. INTRODUCTION This manual describes how this product works and how to get the most out of it in terms of performance. The FS-D weighing indi

Page 21 - 11. SPECIFICATIONS

4 3. UNPACKING Unpack the indicator carefully and keep the packing material if you are likely to transport the indicator again in the future. W

Page 22 - 11-4. Dimensions

5 4. INSTALLATION and PRECAUTIONS 4-1. Precautions for Installing the Indicator  Ground the indicator so that the user will not be subjected an

Page 23

6 Setscrew BSetscrew A 4. Solder the wires to the pin contacts of the connector.  A 5 m or less load cell cable is recommended as the FS-D uses

Page 24 - BackCover 1WMPD4000058J

7 4-4. Setting Up the Indicator  Connect the main power cord to an outlet that has an earth ground terminal. You may use the ear