Table 6 Input Register memory map
Input Register (Read only Word data Reference No. 3)
Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Unit Decimal point position First word
of Input Register
Setting value Setting value
Unit Decimal point position
0: None
1: g
2: kg
3: t
4: lb (USA version)
0: None 123456
1: 10
1
12345.6
2: 10
2
1234.56
3: 10
3
123.456
4: 10
4
12.3456
5: 10
5
1.23456
15 14 1213 11 10 9 78653 4 2 1 0
Status bits
Second word
of Input Register
Bit
FRAM erro
r
Calibration erro
r
Mode erro
r
Zero erro
r
Tare erro
r
Net display erro
r
Checksum erro
r
Input (A/D) erro
r
Gross ove
r
Gross unde
r
Input (A/D) ove
r
Input (A/D) unde
r
Reserved internall
y
Reserved internall
y
Net ove
r
Net unde
r